See power, route and device state before a technician leaves.
Edge intelligence / remote assurance
The remote site that knows what’s happening.
Power. Connect. Observe. Recover. Solatude 01 unifies energy, edge compute and resilient communications in one integrated remote-site platform.
01 Platform concept · current architecture + next-generation roadmap
Remote infrastructure should explain itself.
Most remote systems are assembled from separate power, network, camera and telemetry products. When one fails, the operator sees symptoms — not causes.
Solatude 01 brings those layers under one policy and one operating picture. It keeps working at the edge, uses the best available path to report home and preserves a separate route for recovery.
Use the out-of-band path for controlled recovery workflows.
Join telemetry, actions and media in a single incident timeline.
Four jobs. One field platform.
Choose a layer to see how Solatude turns fragmented field hardware into a system that can observe, decide, act and report.
Know where every watt is going.
Solar, battery and load telemetry become one operating picture. Metered outputs can be prioritised, switched and recovered without a site visit.
- Solar and battery telemetry
- 4 × managed field outputs
- 12 V / 24 V regulation options
Built as a site controller, not another appliance.
Compute, switching, power supervision and separate communications paths share one designed architecture — so the platform can see the dependencies that ordinary routers cannot.
DESIGN TARGET
NXP i.MX 95 + 2 TB
More local intelligence, more retained evidence and more autonomy. The i.MX 95 family adds heterogeneous real-time compute, an NPU delivering up to 2 TOPS and hardware security foundations for advanced edge workloads.
- CPU family
- Up to 6 × Cortex-A55 + M7 / M33
- Edge AI
- Up to 2 TOPS eIQ Neutron NPU
- Local archive
- 2 TB onboard solid-state storage
- Security
- EdgeLock + secure identity options
Concept render. Final enclosure, connector positions and electrical ratings remain subject to engineering release.
One node sees the whole site.
Solatude correlates energy, devices and communications before it takes an action. That context is what separates remote assurance from a simple “online / offline” check.
Inputs
- PV + batteryVoltage, current, charge and energy state
- 4 × Ethernet / PoELink, traffic, power draw and device state
- WAN paths5G, Starlink, Wi-Fi and OOB health
- Field signalsCameras, BLE, Sub-GHz and sensor events
Outputs
- Managed powerPrioritise, isolate and restart field loads
- Resilient routingSelect application path and preserve recovery
- Local responseRecord, notify, illuminate and announce
- Operational evidenceAlerts, audit trail, incident media and APIs
A fleet view with field-level truth.
The cloud does not replace the edge. It gives operators a secure way to understand it, manage desired state and coordinate action across every deployed site.
Different sites. The same operating problem.
Choose a scenario to see how the hardware, links and field actions can be assembled around the job rather than a fixed product bundle.
Site security
A construction compound after everyone leaves.
PoE cameras, local recording, 5G and optional Starlink remain visible as one system. A verified intrusion can trigger SolarSeer locally while the cloud assembles the event and escalation trail.
Reduce blind dispatches and preserve usable evidence even when the primary link is degraded.
SPEAKER · RGB ALERT · MULTI-BAND RADIO
Give the remote site a voice.
SolarSeer extends Solatude from observation into local communication. Its design combines a programmable RGB strobe-style visual alert, digital audio, BLE, Sub-GHz radio and motion sensing in a field companion.
Make the edge response visible and audible.
Use the 24 individually addressable RGB LEDs and digital audio path for graduated, site-specific responses — from an amber pre-warning to a spoken instruction or high-priority alarm pattern.
- Visual
- 24 × individually addressable RGB LEDs
- Audio
- I²S Class-D amplifier + speaker path
- Radio
- CC1352P7 · BLE 5.2 capable · Sub-GHz design variants
- RF path
- 20 dBm design path · 433 / 915 MHz variants
- Motion
- LIS2DW12 3-axis accelerometer
- LPWA / GNSS
- Optional Quectel modem footprint; populated variant TBC
- Board rails
- 3.8 V / 1 A · 3.3 V / 1 A · 1.8 V / 0.3 A from 5 V
Concept render. The design supports configurable visual and audio patterns; no life-safety, emergency-warning, candela or acoustic compliance is claimed.
Size from the load, not the wish.
Adjust the assumptions to see the relationship between continuous load, usable battery energy and solar recovery. This corrects a common remote-power mistake: nominal battery capacity is not the same as delivered autonomy.
MODEL OUTPUT
92% battery-to-load efficiency, 80% net solar yield and 30% PV sizing margin. This does not model a defined recharge deadline. Cable losses, temperature derating, ageing and shading require site engineering.
At 50 W continuous, a 3 kWh battery is not a five-day system. With an 80% usable window and 92% conversion efficiency, it delivers about 44 hours. Five battery-only days need approximately 8.2 kWh nominal before environmental margin.
Known, targeted and still to be released.
This concept separates confirmed architecture from roadmap targets and configuration-dependent ratings. It is intentionally more useful than a specification sheet filled with invented numbers.
Scroll horizontally to compare current and next-generation specifications →
| System | Specification | Current platform | Next generation / option | Status |
|---|---|---|---|---|
| Compute | Application processor | NXP i.MX 8M Mini — up to 4 × Cortex-A53 + Cortex-M4 | NXP i.MX 95 — up to 6 × Cortex-A55 + Cortex-M7 / M33 | Current / target |
| Compute | AI acceleration | Workload-dependent software acceleration | Up to 2 TOPS eIQ Neutron NPU | Target |
| Compute | Local storage | Configuration dependent | 2 TB onboard solid-state storage | Target |
| Network | Ethernet / PoE | 4 × Gigabit Ethernet with managed PoE | 4 × Gigabit Ethernet with managed PoE | Current / target |
| Network | Application cellular | Quectel RM520N; 5G Sub-6, 3GPP Release 16, SA / NSA | RM520N-class 5G or release configuration | Config / TBC |
| Network | Out-of-band cellular | Separate management cellular path | Separate low-power management path | Current / target |
| Network | Wi-Fi | Intel module; bands / generation set by build | Module option set by build | Config / TBC |
| Power | Solar input | Solar-input architecture; regulation topology, voltage and current ratings TBC | Site-configured solar input; electrical release TBC | Config / TBC |
| Power | Field outputs | 4 × metered, switchable outputs; 12 V / 24 V regulator options | 4 × managed outputs; final rail ratings TBC | Config / TBC |
| Power | Regulated DC rails | 12 V / 24 V architecture; current and transient limits TBC | Site-load-specific regulator configuration | Config / TBC |
| Power | PoE power budget | PSE class, per-port and aggregate budget TBC | Configured to camera / radio load plan | Config / TBC |
| Power | Last-gasp reserve | 18650-backed last-gasp reporting reserve; supported functions and runtime TBC | Dedicated reserve; supported functions and runtime TBC | Config / TBC |
| WAN | Starlink Mini integration | Supported in appropriately sized DC / routing configuration | Integrated high-bandwidth WAN option | Config / TBC |
| Security | Device identity | TPM2 / secure-element architecture options | i.MX 95 EdgeLock + secure identity options | Target |
| Software | Device management | Planned: health telemetry, desired / reported state and allow-listed commands | Adds expanded edge AI and orchestration | Target |
| Software | Cloud patterns | Planned managed multi-tenant, dedicated-tenant and hybrid choices | Same deployment choices | Target |
Starlink publishes 25–40 W average consumption and a 12–48 V DC, 60 W input rating. Solatude integration therefore requires a correctly sized DC rail and energy budget; it should not be inferred from a generic PoE port.
The four managed channels are part of the architecture. IEEE class, per-port limit and aggregate PSE budget remain engineering-release items and are not fabricated here.
Enclosure IP rating, operating temperature, dimensions, certifications, PV limits, regulator current and battery chemistry must be added when production variants are frozen.
Build the field layer once. Add intelligence over time.
See and recover
Planned: unified health, metered outputs, resilient routes, local recording, alerts and controlled remote commands.
Understand the event
Edge AI classification, incident packages, predictive battery and link-health models, fleet policy and automated response.
Coordinate the site
Cross-device reasoning, adaptive energy budgets, local natural-language operations, multi-node radio meshes and autonomous service workflows.
Start with the site profile
What needs to stay working when nobody is there?
Define the loads, autonomy, communications and response policy. Solatude can then be configured around the real operating problem.
Model site energy